Formfloor » Outdoor Applications http://formfloor.com.tr/en Yükseltilmiş Döşeme Sistemleri Mon, 22 Feb 2016 10:12:45 +0000 tr-TR hourly 1 https://wordpress.org/?v=3.8.26 Outdoor Raised Access Flooring http://formfloor.com.tr/en/2013/12/21/dis-mekan-yukseltilmis-doseme-2/ http://formfloor.com.tr/en/2013/12/21/dis-mekan-yukseltilmis-doseme-2/#comments Sat, 21 Dec 2013 16:47:09 +0000 http://demo.renklisayfa.net/form-floor/?p=335 dis_mekan_1 dis_mekan_2 dis_mekan_3

Mosque courtyards, patios, poolsides, open air venues are some application areas of outdoor raised access floors. In addition to all benefits of the system in the outdoor usage, it is more quick and easy to discharge the water in rainy days. And the area keeps clean and safe. Natural or artificial marble and stone can be used on the plastic pedestals.
According to TS EN 12825 standard, our outdoor pedestals to have a 2,000 kg load bearing capacity. This capacity satisfies the vertical load specified in EN 12825 standard; where system work load is declared to have at least 4 times the pedestal vertical load capacity.

]]>
http://formfloor.com.tr/en/2013/12/21/dis-mekan-yukseltilmis-doseme-2/feed/ 0
Outdoor Substructure Properties http://formfloor.com.tr/en/2013/12/21/dis-mekan-yukseltilmis-doseme/ http://formfloor.com.tr/en/2013/12/21/dis-mekan-yukseltilmis-doseme/#comments Sat, 21 Dec 2013 16:46:54 +0000 http://demo.renklisayfa.net/form-floor/?p=333 dis_mekan_altyapi_1 dis_mekan_altyapi_2 dis_mekan_altyapi_3

PEDESTAL PROPERTIES
Pedestal Base: Black coloured hard polyamide material
Pedestal Head: Black coloured hard polyamide material
Pedestal Body : Black coloured polyethilene pipe sized according to customer needs

Shim: Black coloured polyethilene round-shaped shim for adjusting level differences.

PEDESTAL VERTICAL LOAD TEST:

Before the test procedure, pedestal base, body and head are placed on a rigid substratum. The 50×50 mm indentor shall be placed exactly over the center of pedestal head on top of the panel. A steadily increasing load is applied via the indentor until a failure of any elements occurs. The understructure has to support 4 times the working load of the system tested not becoming distorted or damaged.

 

]]>
http://formfloor.com.tr/en/2013/12/21/dis-mekan-yukseltilmis-doseme/feed/ 0